Manufacturers

ROBERT RIELE GmbH & Co.KG

Kurfürstenstr. 75-79 , 13467 Berlin
Germany

Telephone +49 30 4044087
Fax +49 30 4040529
info@riele.de

This company is main exhibitor of

Trade fair hall

  • Hall 3 / F06
 Interactive Plan

Hall map

MEDICA 2016 hall map (Hall 3): stand F06

Fairground map

MEDICA 2016 fairground map: Hall 3

Our range of products

Product categories

  • 02  Laboratory Equipment
  • 02.01  Analyser appliances

Analyser appliances

  • 02  Laboratory Equipment
  • 02.01  Analyser appliances
  • 02.01.13  Filter photometers

Filter photometers

  • 02  Laboratory Equipment
  • 02.01  Analyser appliances
  • 02.01.28  Cuvettes for glass photometers

Cuvettes for glass photometers

  • 02  Laboratory Equipment
  • 02.01  Analyser appliances
  • 02.01.29  Cuvettes for synthetic photometers

Cuvettes for synthetic photometers

  • 02  Laboratory Equipment
  • 02.01  Analyser appliances
  • 02.01.41  Photometers

Photometers

  • 02  Laboratory Equipment
  • 02.01  Analyser appliances
  • 02.01.42  Accessories for photometers

Accessories for photometers

  • 02  Laboratory Equipment
  • 02.01  Analyser appliances
  • 02.01.64  Temperature regulation equipment

Temperature regulation equipment

  • 02  Laboratory Equipment
  • 02.01  Analyser appliances
  • 02.01.69  Dry warm up devices

Dry warm up devices

  • 03  Diagnostics
  • 03.01  Clinical chemistry
  • 03.01.08  Devices and systems for glucose determination units

Devices and systems for glucose determination units

  • 03  Diagnostics
  • 03.01  Clinical chemistry
  • 03.01.10  Devices and systems for haemoglobin determination

Devices and systems for haemoglobin determination

  • 03  Diagnostics
  • 03.01  Clinical chemistry
  • 03.01.12  Units and systems for clinical chemical determination

Units and systems for clinical chemical determination

Our products

Product category: Filter photometers

Photometer 5010 V5+

Type: Semi-automatic, single-beam filter photometer
Light Source: Halogen lamp – 12 V, 20 W with protection for lifetime
Wavelength: 340 nm – 800 nm
Wavelength Selection: Automatic via 9-position filter wheel :
6 standard interference filters: 340 nm, 405 nm, 492 nm, 546 nm, 578 nm and 623 nm;
3 positions for optional filter of choice
Photometric Range: 0 – 2.5 A
Cuvette System: Micro flow cell: 32 µl, 10 mm light path interchangeable with normal standard cuvettes (macro or semi-micro, disposable or special optical glass)
Temperature Control:  • Internal Peltier element, temperature variable, pre-adjusted to 25 °C, 30 °C and 37 °C
                                   • Equilibration time for aspirated reaction mixture to reach 37 °C from ambient temperature: 15 sec

Aspiration System: Built-in peristaltic pump driven by stepper motor, programmable aspiration volume controlled by infrared light barrier
Sipping Volume: • Minimum 250 µl, typically 500 µl up to 2000 µl
                          • Separate setting of aspirate volume and wash volume

Operator Interface: Touchscreen for direct functions and alphanumerical inputs
Data Presentation: Graphic display: white characters or symbols, blue backlight, dimension 240 * 128 dots
Integrated Printer: Thermal printer, 24 characters per line
Languages: English and French / German / Indonesian / Russian / Spanish
Memory:  • General operating software can be updated by PC
               • Reagent open system with capacity for up to 231 programmable methods
               • Import of data by touchscreen or PC
               • Up to 50 non-linear calibration curves with max 20 sets of points can be stored

Data Logging: Up to 1000 results can be saved in the memory
Signal Port: Serial port for connection to an external printer and/or PC
Measurement Procedures:   •  Absorbance
                                          • End Point with factor, standard or multiple standards, with or without reagent blank and/or sample blank
                                          • Bichromatic end point
                                          • Kinetics with standard, factor or multiple standards, with or without blank
                                          • Fixed time with standard, factor or multiple standards, with or without reagent blank
                                          • Turbidimetry
                                          •  Single, double and triple determinations
                                          • Curve fitting for non-linear standard curves
                                          • Free hemoglobin in combination with optional interference filters

Quality control: Up to 50 methods can be controlled with two control sera
Levey Jennings plot
Measuring Time:  •  Kinetic: variable from 5 – 19 deltas, time per delta 4 – 255 sec in 1 sec steps
                           • Fixed time: variable from 0 – 1800 sec in 1 sec steps

Delay Time: Programmable from 0 – 1800 sec in 1 sec steps
Mains Supply: Range: 100 VAC up to 264 VAC at 50/60 Hz
Dimensions: Length 33 cm x width 34 cm x height 18 cm
Weight: 5.3 kg