ERNA Tibbi Cihazlar Imalat ve Teknik Servis Limited Sirketi

1819., Street No:7 Ergazi , 06370 Ankara
Turkey

Telephone +90 312 2572121
basak.aktay@erna-medical.com

Trade fair hall

  • Hall 12 / D35
 Interactive Plan

Hall map

MEDICA 2016 hall map (Hall 12): stand D35

Fairground map

MEDICA 2016 fairground map: Hall 12

Our range of products

Product categories

  • 01  Electromedical equipment / Medical Technology
  • 01.06  Sterilisation
  • 01.06.02  Sterilisation and disinfection equipment and accessories / autoclaves

Our products

Product category: Sterilisation and disinfection equipment and accessories / autoclaves

Steam Sterilizers

FEATURES OF SOFTWARE AND PROGRAMS
Erna Sterilizers have all the standard sterilization and testing programs such as; 134 C programs, 121 C programs, user Programs. Additionally, Bowie&Dick Test and Air Leakage Test programs. It is possible to customize programs according to the requirements of the user.

DOCUMENTATION
An alpha-numeric printer, prints the date, program selected and parameters of the program, at the start. Then, the
time, temperature and pressure is recorded periodically. An independent electronic paperless recorder can be adapted; to record chamber temperature and pressures. Erna sterilizers have the archive program for the purpose of validation applications.

The date, time, name of the user, lot number of the containers or the packages of the sterilization process can be stored for years in case of necessity. These data can be searched, sorted and printed out by the user. Bar-coding applications can be realized as well.

AUTOMATIC COMMAND AND CONTROL
Automatic unit controls all the sterilization process and parameters with an industrial type of microprocessor, namely PLC. It has the international standards and approvals with its high quality. For updating the programs, it is possible to be online with the PLC and to download new programs from the ERNA center.

AUTOMATIC CONTROL DISPLAY
Different types of display can be used in the system, in order to get automatic command and control. The display can be LCD with soft-key (membrane keyboard) buttons or LCD with touch screen display or it can be even a graphical LCD display. All types of display have also the international standards with its high quality.

OPERATOR PANEL
The operator panel is a touch screen. Program parameters and cycle information is displayed on the panel. Program selection, start, interruption and manual control is achieved by using a touch panel. They have internationally accepted approvals and high quality.

PRINTER
The printer is heat and humidity resistant. It records all the sterilization process and parameters. The printer is a panel type printer and can be assembled easily to the sterilizer.

ELECTRICAL STEAM GENERATOR
The integrated electrical steam generator is designed to supply necessary saturated steam for the sterilizers. The Pressure is controlled electronically by a pressure transmitter and checked by a pressure switch for safety.

More Less

Product category: Sterilisation and disinfection equipment and accessories / autoclaves

Formaldehyde/Steam Sterilizers

This range of ERNA sterilizers combines steam sterilization with the low temperature steam and formaldehyde (LTSF) sterilization of heat-sensitive items. Combining two sterilization methods into single equipment increases the efficiency incredibly.

Formaldehyde / Steam sterilizers are designed especially for the Central Sterilization Departments. ERNA’s wide range of dimensions helps to meet different needs of the hospitals. The sterilizer is designed to meet the highest standards of safety.

Automatic unit commands and controls all the sterilization process and parameters with an industrial type of microprocessor, PLC. Once the Steam or FO mode is selected, it is possible to operate the sterilizer as if it is steam or FO sterilizer. Mode can be changed in a short time.

Highlights of ERNA Formaldehyde & Steam Sterilizers
1.Temperature range: 650C – 750C (Formaldehyde mode) -1210C – 1340C (Steam mode)
2.Sterilization agent: 2% Formaldehyde Solution(Formaldehyde mode), – Saturated steam(Steam Mode)
3.Lower operating cost
4.Delicate Heating With Steam
5.Water Ring Vacuum Pump
6.Chamber : S/S 316L Quality and Heating Jacket : S/S 304L
7.Vertically Sliding Door(s) with Optional Automatic Door(s)
8.Pass Through models are available
9.Air Filter (0.2 Micron)
10.Stainless Steel Piping in steam & formaldehyde gas lines

Superior quality ERNA Formaldehyde Sterilizers vary between 128 lt – 549 lt. and are manufactured as horizontal and vertical models. For each model single as well as double door options are available
•AISI 316L chamber with 10 years of warranty
•High quality spare parts with renowned brands
•Reliable automatic control with PLC
•Easy manual operation by touch panel
•Validated programs
•Alphanumeric printer
•Independent recorder (optional)
•Water ring type vacuum pump
•Pneumatic valves
• 2% Formaldehyde solution as sterilizing agent in bags
•Delicate heating with steam under vacuum
•Full-fledged technical service
•Complied with EN 14180
•Certified according to 93/42/EEC and 97/23/EC or ASME certified chamber (optional)
•Upon request combined model of steam and formaldehyde sterilizer can be manufactured

•Automatic and the double door options are available for the models above
•Chamber depth is increased by 5 cm for the double-door models
•Standard chamber dimensions may be altered by 5% according to the customer requirements.
•Standard external sizes may be adjusted as per installation site specifications

More Less

Product category: Sterilisation and disinfection equipment and accessories / autoclaves

Industrial EtO Gas Sterilizer

ERNA Ethyleneoxide gas sterilizers are designed to sterilize thermolabile medical equipment at low temperatures (37 – 550 C).Industrial type ERNA EtO sterilizers are designed to sterilize medical equipment or packed disposable medical products at low temperatures (37 – 55 0 C). Sterilizers are designed for the specific client sites with modular systems such as: EtO gas circulation, automatic bottle changeover, EtO scrubber and EtO / H2O concentration sensor.

DOCUMENTATION
A printer is standard part of each sterilizer. It prints the date, programselected and parameters of the program, at the start. Then, the time,temperature and pressure is recorded periodically. Optionally, a paperless – electronic recorder can be integreted to the sterilizer control. The graphs of temperature and pressure is saved in its flash memory, and can be copied to a PC in order to be stored for years.

AUTOMATIC COMMAND CONTROL
The automatic unit mainly consists of an industrial type microprocessor, namely PLC. It is reliable with its high
quality and international approvals. It controls all the sterilization process and parameters. With the help of a modem, it is possible to be online with the PLC and to download new programs from the ERNA center.

OPERATOR PANEL
The operator panel is a touch screen. Program parameters and cycle information is displayed on the panel. Program selection, start, interruption and manual control is achieved by using a touch panel. They have internationally accepted approvals and high quality.Different types of display can be used in the system, in order to monitor the process.

FEATURES OF SOFTWARE AND PROGRAMS
ERNA Ethylene Oxide Gas Sterilizers have six open programs and leakage test programs. The parameters of open programs can be set by autorize person of user. It is possible to customize programs prior to delivery, according to the requirments of the user.

PRINTER
The printers is heat and humidity resistant. It records all the sterilization process and parameters. The printer is a panel type printer and can be assembled easily to the sterilizer.

ELECTRICAL STEAM GENERATOR
The integrated electrical steam generator is designed to , supply necessary saturated steam for the sterilizers. It is controlled by PLC and a oressure switch, for safety.

EtO Sterilization Main Parameters
•Temperature
•EtO Concentration
•Humidity
•Exposure Time

All these parameters define the pressure inside the chamber

Highlights of Industrial Type Ethylene Oxide Sterilizers
•Chamber : S/S 316L Quality with 5 years of warranty
•Automatic Control with PLC
•Easy manual operation by touch panel
•Alphanumeric printer
•Independent electronic recorder
•Pneumatic valves
•Sterilization at vacuum
•Volume up to 30 m3
•Heating Jacket : S/S 304L Quality, water circulation in 3 different regions
•Heating Skid: Steam Generator for humidification, and two Heating Tanks
•Vacuum Pump: •Water ring type or
•Oil ring type

ERNA EtO Sterilizer Mechanical Components:
•EtO Gas Circulation System – For homogeneous distribution of: temperature, EtO concentration and humidity)
•Evaporator & Vacuum Pump
•Automatic Bottle Changeover Sys.
•EtO Scrubber System
•EtO / H2O Concentration Sensor (infrared technology)

More Less

Product category: Sterilisation and disinfection equipment and accessories / autoclaves

Medical Waste Steam Sterilizers

ERNA medical waste steam sterilizers process the medical waste after full sterilization and shredding cycles. The treated waste can be unloaded to be disposed safely as general waste. Air and steam outlets at chamber are HEPA filtered.

•Two Separate Steam Generators
•Heavy Duty Built-In Shredder
•Chamber : S/S 316L Quality
•Heating Jacket : S/S 304L
•Vertical or Horizontally Sliding Doors
•Semi-Automatic Opening/Closing System for the Doors (With Pneumatic Cylinders)
•Stainless Steel Piping
•Sterilization of both Loading&Unloading Chambers and Shredder simultaneously
•Easy loading and unloading

More Less

About us

Company details

With over 30 years of manufacturing experience and more than 600 sterilizers operating worldwide, ERNA has consolidated its position as the pioneer of quality and reliability in steriliser equipment area.

 

ERNA sterilisers are manufactured according to

ISO 9001:2008,
EC Directive 93/42 EEC (MDD),
EC Directive 97/23 EC (PED),
EN ISO 13485:2003
Certificate of Conformity of Turkish Standards

ERNA is recognized by the "Superior Achievement Prize" of the Turkish Health Digest and holds Free Sales Certificate.

Highly qualified technical ERNA R&D and production teams along with the flexible technical service team work in modern production facilities to produce high quality sterilisers and aim accomplishing constant high customer satisfaction.

With an ongoing commitment to maintain and improve the quality and standards ERNA follows the Quality Management Policy: “By following the technological developments, according to the needs of users, to manufacture the functional, reliable and aesthetic equipment and after the sale to continue the customer satisfaction by the support of technical service."

We look forward to meeting in our booth in Medica to demonstrate our superior quality sterilisers.

More Less

Company data

Sales volume

1-9 Mio US $

Export content

max. 75%

Number of employees

20-49

Foundation

1989

Area of business

Electromedical equipment / Medical Technology