Manufacturers

Feas Electronica S.A.

Av. Colón 5760 , X5003DFP Cordoba-Quebrada de las Rosas
Argentina

Telephone +54 351 4848016
Fax +54 351 4850750
shaas@feaselectronica.com.ar

Trade fair hall

  • Hall 9 / B36
 Interactive Plan

Hall map

MEDICA 2016 hall map (Hall 9): stand B36

Fairground map

MEDICA 2016 fairground map: Hall 9

Our range of products

Product categories

  • 01  Electromedical equipment / Medical Technology
  • 01.03  Therapie and physical medicine
  • 01.03.06  Cardiac therapy equipment

Cardiac therapy equipment

  • 01  Electromedical equipment / Medical Technology
  • 01.03  Therapie and physical medicine
  • 01.03.06  Cardiac therapy equipment
  • 01.03.06.02  Defibrillators and accessories

Defibrillators and accessories

  • 01  Electromedical equipment / Medical Technology
  • 01.03  Therapie and physical medicine
  • 01.03.06  Cardiac therapy equipment
  • 01.03.06.04  Manually operated external defibrillators

Manually operated external defibrillators

  • 01  Electromedical equipment / Medical Technology
  • 01.04  Intense medicine / anesthesiology / respiration
  • 01.04.04  Patient monitoring systems / Measuring stations
  • 01  Electromedical equipment / Medical Technology
  • 01.04  Intense medicine / anesthesiology / respiration
  • 01.04.04  Patient monitoring systems / Measuring stations
  • 01.04.04.09  Patient monitors

Patient monitors

Our products

Product category: Patient monitoring systems / Measuring stations

Multiparameter Patient Monitor

•Menu, messages and instructions in English.
•Single sweep speeds for circulatory  and respiratory system: 12.5, 25 and 50 mm/s.
•Visual and audible QRS indicator proceeding fromECG or Oxymeter.
•When QRS proceeds from the Oxymeter, the sound changes its tone as SpO2 modifies.
•Three alarm levels: physiologicals, technicals and generals.
•Upper and lower limits adjustable by the user.
•Visual and audible alarm indicators, on screen and on top of the equipment.
•Hotkey to activate the silent alarms for 2 minutes.
•Alarms Turn Off.
•User friendly menu by using the selector knob and hotkeys.
•Waveform print-out on standard printer.
•Analog outputs for ECG, RESP, IBP and a synchronization pulse.
•Video output for slave or remote monitor (optional).
•Networking Connection for Centralized Monitoring.
•WAIT Mode: stops monitoring, which allows changing to another patient without activating the alarms.
•Screen menu:
  •Normal.
  •7 leads of ECG.
  •Tabular trends or graphical trends.
  •Frozen and measuring of calipers.
  •Large numbers.

More Less

Product category: Patient monitoring systems / Measuring stations

Central Monitoring Station

•Monitoring capacity: 4, 8, 12 or 16 patients simultaneously (according to model).
•Observation of Waveforms:
◦ELECTROCARDIOGRAM.
◦INVASIVE BLOOD PRESSURE.
◦RESPIRATORY OR PLETHYSMOGRAPH.
•Digital communicaton with bedside feas ELECTRONICA monitors, for the reception of values of: ECG, Respiratory, SpO2, Pulse Rate, EtCO2, Invasive Blood Pressure, Temperature, Non-Invasive Blood Pressure, FiCO2 and Respiratory Rate.
•Audible and visual alarms by maximum and minimum, configurable for all the parameters; with volume control.
•Enter text on screen (Patient Case History).
•Freeze waveform of selected patient.
•Observe previous events.
•Trend graphs. Graphic or tabular trend of the last 72 hours, displayed on 1, 4, 8, 12, 24, 48 and 72 hours.
•High resolution printing of: saved waveforms and values for heart rate; systolic, diastolic and mean pressures, respiratory rate and trends for all the parameters.
•Reception of signals from other brand monitors or acquired from bedside monitors or preamplifiers.

More Less

Product category: Defibrillators and accessories

Monitor Defibrillator Biphasic

MONITOR

•Electrocardiogram Monitor with LCD screen.
•Electrocardiogram Signal acquired through 3 or 5 leads patient cable or through paddles
•Leads selection:
◦with 3 leads cable: DI, DII, DIII.
◦with 5 leads cable: DI, DII, DIII, aVR, aVF, aVL and Precordial.
•ECG waveform Cascade.
•Digital indication of heart rate.
•Low battery indicator.
•Luminous indicator of Battery Charging.
•Alarms Silence key.
•Alarms for Heart Rate from 20 [1/min] to 250 [1/min].
•ECG gain: 1/6, 1/4, 1/2, 1 y 2 [cm/mV].

DEFIBRILLATOR

•Biphasic waveform.
•Defibrillator use in three steps:
1.Turn on and select energy.
2.Charge.
3.Trigger energy discharge by means of pushbuttons on the paddles or from keyboard.
•Selector switch for charge selection by steps: 2, 3, 5, 7, 10, 20, 30, 50, 70,100, 150 and 200 [Joules].
•Visual and audible indication of charging process completed.
•Stored energy indication on display.
•Energy discharge through paddles by pushing, simultaneously, both pushbuttons on paddles.
•Charge is cancelled internally when: The key “Disarm” is pressed or when 60s have elapsed since charge process was completed or when selector switch is turned to MONITOR or OFF. In these cases the energy is discharged internally without reaching the paddles.
•Direct or synchronized discharge.
•Visual and audible indication of synchronized mode.
•Discharge Capacity: 150 discharges at maximum energy, with fully charged internal battery.
•Charger time to 200J: Less than 6s.

TEST OF ENERGY DELIVERED

More Less

Product category: Cardiac therapy equipment

Polygraph study hemodynamic

•ELECTROCARDIOGRAM
◦Heart rate: 20 to 300 b.p.m. ± 1 b.p.m.
◦Gains selection: 1/4; 1/2; 1; 2 and 4 cm/mV.
◦Visual and audible QRS beep.
◦1 Channel:
◾3 leads patient cable: DI, DII or DIII.
◦2 Simultaneous channels:
◾5 leads patient cable: DI, DII, DIII, AVR, AVL, AVF and V.
◾10 leads patient cable: DI, DII, DIII, AVR, AVL, AVF, V1, V2, V3, V4, V5, V6.

•INVASIVE BLOOD PRESSURE
◦2 channels of invasive blood pressure.
◦2 Additional channels of invasive blood pressure (optional).
◾Systolic, diastolic and mean pressure measurement.
◾Pressure ranges selectable between automatic or manual mode, between -25 mmHg and 475 mmHg.
◾Display of systolic, diastolic and mean pressures simultaneously.
◾Edition of labels with name of selected pressure waveform:
ART: Arterial Pressure
AO: Aortic Pressure
LV: Left Ventricle Pressure
PA: Lung Artery Pressure
PAW: Pulmonary-Capillary Wedge Pressure
RV: Right Ventricle Pressure
RA: Right Atrium Pressure
LA: Left Atrium Pressure
or Edited by the user.
◾Mean pressure waveform.
◾dP/dt waveform.

•CARDIAC OUTPUT
◦Selection of:
Volume of injectate 3, 5 and 10 ml.
Constant K of catheter or computing constant CC.
◦Measurement of blood temperature.
◦Calculation of:
BSA: body surface
CO: cardiac output
VS: systolic volume
CI: cardiac index
SI: systolic index

•TEMPERATURE
◦Measurement of body temperature or of the injected for
cardiac output.
◦Temperature range: -5ºC to 45ºC.

•ALARM
◦Audiovisual alarm for superior limit or inferior limit of any of the
parameters:
◦Heart Rate, Mean Pressure, Temperature and SpO2, FP (optional)

•HEMODYNAMIC CALCULATIONS
◦Calculation of valvular areas by 2 pressure waveforms
◦Calculation of valvular areas with 1 channel performing pullback.
◦Calculation of vascular and systemic resistance.

•CHRONOMETER: on screen for timing, example: dilatation times, etc.
•IMAGE FREEZE FOR:
◦See up to 100 pages of monitoring stored in memory.
◦Perform measurements on the frozen curves.
◦Print pages frozen at the moment.
◦Store a frozen page

•CALIPER FOR MEASUREMENT OF:
◦Time in seconds
◦ECG Amplitude in mV.
◦Invasive blood pressure in mmHg.
◦dP/dt in mmHg/sec

•MENU IN SPANISH, PORTUGUESE AND ENGLISH.
◦Use of menu through keyboard or mouse.
◦Selection of parameters without losing monitoring

• HARD DISK DATA STORAGE, WHICH ALLOWS:
◦Saving of Patient Case Stdies with patient name and study number.
◦Recover saved Patient Case Studies.
◦Delete saved Patient Case Studies.
◦Footswitch, keyboard or mouse recording command.
◦Printing of saved Patient Case studies.
◦Updating of desired parameter configuration file,
during equipment start-up.

•TRENDS FOR:
◦Heart rate.
◦Systolic, diastolic and mean pressures.
◦Temperature.
◦SpO2 and pulse rate (optional).
◦Display of 1, 8 and 24 hours.
◦Zoom in the scale of 24 hours.
◦Printing of trends.

•SWEEP SPEED
◦Selectable between 25, 50 and 100 mm/sec.
◦Can be modified over studies in progress or saved.

•PRINTING: -Patient case studies.
◦Either fast or high definition printing modes.
◦Recording on paper during progress of monitoring.

•PULSE OXIMETRY (Optional)
◦Plethysmographic waveform
◦Display of SpO2
Range: 0 - 100 %
Accuracy: 100 - 70% ± 2% adult
100 - 70% ± 3% neonate
◦Display of pulse rate
Range: 30 - 250 ± 3 p.p.m.
◦Includes one sensor.

•NON-INVASIVE BLOOD PRESSURE (Optional)
◦Start of measurement in manual mode, or automatic
mode at intervals programmable from 1 minute
to 90 minutes.
◦Patient selection ADULT or NEONATE.
◦Systolic or diastolic pressure alarms.
◦Display of the last 1440 measurements.
◦Print-out of measurements in table form.
◦Includes cuff.
◦This software is also included in the Electrophysiology
and Hemodynamic Poligraph System.

More Less

Product category: Patient monitoring systems / Measuring stations

Polygraph for hemodynamic and electrophysiological studies

ELECTROPHYSIOLOGY AND HEMODYNAMIC POLYGRAPH SYSTEM
SPECIFICATIONS
This equipment contains the necessary elements
for the performing of electrophysiology and
hemodynamic patient case studies, with specific
software for each usage

Electrophysiology Software:
•12 simultaneous surface electrocardiogram
channels with selectable Leads:
DI, DII, DIII, AVR, AVL, AVF,
V1, V2, V3, V4, V5, V6.
Heart rate: 20 to 300 b.p.m.
•18 simultaneous channels of intracavitary ECG.
•2 channels of invasive blood pressure.
•2 Additional channels of invasive blood pressure (optional).
Systolic, diastolic and mean pressure measurement.

PULSE OXIMETRY (Optional)
•Plethysmographic waveform
•Display of oxygen percentual saturation (SpO2)
Range: 0 - 100 %
Accuracy: 100 - 70% ± 2% adult
100 - 70% ± 3% neonate
•Display of pulse rate
Range: 30 - 250 ± 3 p.p.m.
•Includes one sensor.

Non-Invasive Blood Pressure (Optional).
•Start of measurement in manual mode or in
automatic mode at programmable intervals
from 1 minute to 90 minutes.
•ADULT or NEONATE patient selection .
•Display of the last 1440 measurements.
•Print-out of measurements in table form.
•Includes one cuff.
•Sweep speed: 25, 50, 100, 200 and 400 mm/sec.
10 calipers for measurement of time intervals.
•Continuous waveform positioning, gain and limiting.
•Customized label and color for waveforms.
Image freezing:
◦View monitoring pages stored in memory.
◦Edit written notes.
◦Print pages.
•Menu in Spanish, Portuguese and English.
•Use through keyboard or mouse.

Hard disk data storage, which allows:
•Saving of Patient Case Studies with patient name
and Case number.
•Recall of recorded monitoring data in order to perform
its revision, with the possibility of modifying gain,
position,color and waveform limits (amplitude).
•Saving of preselected channel configurations.
•Deleting of saved patient case studies.
•Record command by means of Footswitch,
Keyboard or Mouse.

Rewritable CD drive,
which allows storing and transporting the patient case studies to other equipment or to Personal Computers.

Heart rate measurement.
•Value displayed: beat to beat or averaged.
•Triggered sweep display mode: ◦Selectable trigger waveform: Intracavitary channels
or surface ECG.
◦Adjustable trigger threshold.
◦Trigger by positive (rising)slope or negative (falling) slope.
•Split screen mode ◦Allows using one half of the screen for frozen images,
as a reference, while the other half of the screen
continues monitoring.

Keyboard Quick Command Keys:
•Freeze/Unfreeze.
•Previous/Next Page.
•Previous/Next Section
•Start/Stop Recording
•New Caliper
•Sweep speed
•Toggles between the two last curves configurations.
•Toggles between 12 ECG configuration

More Less

About us

Company details

Established in 1983, FEAS ELECTRONICA S.A. is in the business of providing high quality technical expertise to the healthcare and medical communities. FEAS ELECTRONICA S.A. specializes in manufacturing Medical Equipment and in building software applications, and hardware solutions to improve the life quality of patients. Our company makes several kind of equipment as follows: -Multiparameter Monitor -Cardiac Monitor -Non Invasive Blood Pressure Monitor -Pulse Oxymeter -Oxycapnography Monitor -Capnograph -Monitoring Central Station -Hemodynamic Polygraph System -Electrophysiology and Hemodynamic Polygraph System -Radio Frequency Ablator -Programmable Cardiac Stimulator -Portable Defibrillators Contact us at: Phone: +54-351-4848016 or 18 Fax: +54-351-4850750 E-mail: feasiee@feaselectronica.com.ar Web page: www.feaselectronica.com.ar

More Less

Company data

Sales volume

200-499 Mio US $

Export content

max. 10%

Number of employees

50-99

Foundation

1984

Area of business