Propper Manufacturing Co., Inc. of Long Island City, NY at MEDICA 2017 in Düsseldorf -- COMPAMED Trade Fair
Manufacturers OEM

Propper Manufacturing Co., Inc.

36-04 Skillman Avenue, 11101 Long Island City, NY
United States of America

Telephone +1 718 392-6650
marketing@proppermfg.com

Hall map

MEDICA 2017 hall map (Hall 12): stand A18

Fairground map

MEDICA 2017 fairground map: Hall 12

Contact

Kelly House

New York

Email
marketing@proppermfg.com

Our range of products

Product categories

  • 01  Electromedical equipment / Medical Technology
  • 01.01  Diagnostics
  • 01.01.01  General Diagnostics

General Diagnostics

  • 01  Electromedical equipment / Medical Technology
  • 01.01  Diagnostics
  • 01.01.01  General Diagnostics
  • 01.01.01.02  Instruments and apparatus for ocular diagnosis

Instruments and apparatus for ocular diagnosis

  • 01  Electromedical equipment / Medical Technology
  • 01.06  Sterilisation
  • 01.06.02  Sterilisation and disinfection equipment and accessories / autoclaves

Sterilisation and disinfection equipment and accessories / autoclaves

  • 01  Electromedical equipment / Medical Technology
  • 01.06  Sterilisation
  • 01.06.02  Sterilisation and disinfection equipment and accessories / autoclaves
  • 01.06.02.03  Biological indicators for sterilisation

Biological indicators for sterilisation

  • 01  Electromedical equipment / Medical Technology
  • 01.06  Sterilisation
  • 01.06.02  Sterilisation and disinfection equipment and accessories / autoclaves
  • 01.06.02.04  Chemical indicators for sterilisation
  • 01  Electromedical equipment / Medical Technology
  • 01.06  Sterilisation
  • 01.06.02  Sterilisation and disinfection equipment and accessories / autoclaves
  • 01.06.02.07  Accessories for disinfection

Accessories for disinfection

  • 01  Electromedical equipment / Medical Technology
  • 01.06  Sterilisation
  • 01.06.02  Sterilisation and disinfection equipment and accessories / autoclaves
  • 01.06.02.08  Apparatus for cleansing and disinfection
  • 01  Electromedical equipment / Medical Technology
  • 01.06  Sterilisation
  • 01.06.02  Sterilisation and disinfection equipment and accessories / autoclaves
  • 01.06.02.19  Sterile goods packaging and sterilisation indications

Sterile goods packaging and sterilisation indications

  • 01  Electromedical equipment / Medical Technology
  • 01.06  Sterilisation
  • 01.06.02  Sterilisation and disinfection equipment and accessories / autoclaves
  • 01.06.02.23  Accessories for sterilising systems and sterilisation

Accessories for sterilising systems and sterilisation

  • 01  Electromedical equipment / Medical Technology
  • 01.06  Sterilisation
  • 01.06.02  Sterilisation and disinfection equipment and accessories / autoclaves
  • 01.06.02.24  Sterilisation control

Sterilisation control

  • 01  Electromedical equipment / Medical Technology
  • 01.06  Sterilisation
  • 01.06.02  Sterilisation and disinfection equipment and accessories / autoclaves
  • 01.06.02.29  Ultraviolet disinfection equipment

Ultraviolet disinfection equipment

  • 01  Electromedical equipment / Medical Technology
  • 01.08  Surgery and Endoscopy
  • 01.08.02  Surgical instruments and products

Surgical instruments and products

  • 01  Electromedical equipment / Medical Technology
  • 01.08  Surgery and Endoscopy
  • 01.08.02  Surgical instruments and products
  • 01.08.02.31  Instruments and apparatus for ophthalmology

Instruments and apparatus for ophthalmology

  • 03  Diagnostics
  • 03.02  Immunochemistry (Immunology)
  • 03.02.17  Tumor markers

Tumor markers

  • 03  Diagnostics
  • 03.02  Immunochemistry (Immunology)
  • 03.02.17  Tumor markers
  • 03.02.17.05  Accessories for tumour marker determination

Accessories for tumour marker determination

  • 05  Commodities and Consumer Goods
  • 05.02  Universal medical commodities

Universal medical commodities

  • 05  Commodities and Consumer Goods
  • 05.02  Universal medical commodities
  • 05.02.17  Sterile bags

Sterile bags

  • 05  Commodities and Consumer Goods
  • 05.02  Universal medical commodities
  • 05.02.19  Sterilisation accessories

Sterilisation accessories

  • 05  Commodities and Consumer Goods
  • 05.09  Disposable articles for laboratories

Disposable articles for laboratories

  • 05  Commodities and Consumer Goods
  • 05.09  Disposable articles for laboratories
  • 05.09.02  Disposable laboratory material made of glass (slides, capillary tubes, pipettes)

Disposable laboratory material made of glass (slides, capillary tubes, pipettes)

Our products

Product category: Biological indicators for sterilisation

BI-OK® Plasma Biological Indicators

BI-OK® Plasma Biological Indicators
Cat. No.: 26923100 – SCBI Vials – 20 vials per pack

Long Island City, NY – August 22, 2017: New from Propper, BI-O.K. Plasma Self-Contained Biological Indicators are intended for use in routine monitoring of VH2O2 sterilizer cycles with or without a plasma phase.

BI-O.K. Plasma Indicators combine a vaporized hydrogen peroxide compatible carrier with Geobacillus stearothermophilus spores (1.0-5.0 x 106) and culture media for ease-of-use and the high level of assurance of a biological indicator result. The label contains a process indicator and can be written on for record keeping purposes and vial identification.

Visit www.proppermfg.com/international or call +1 (718) 392-6650 for more information.

More Less

Product category: Chemical indicators for sterilisation

Plasma-Chex Type 4 Chemical Indicator Strips

Plasma-Chex Type 4 Chemical Indicator Strips
Cat. No.: 26701800 – Indicator Strips – 250 per pack

Long Island City, NY – August 22, 2017: New from Propper, The Plasma-Chex indicator is designed as Type 4 indicator for vaporized peroxide sterilization and intended to be used inside sterilization process to demonstrate attainment of sterilization parameters. The indicator can be used in various types of sterilizers using vaporized peroxide process.

The unprocessed indicator color is red. The indicator will turn yellow after exposure to vaporized peroxide sterilization conditions. Indications of fail conditions are brown, red or orange color of the indicator. Picture below represent typical unprocessed and processed pass color. after sterilization processing both end-point pass Yellow and any shade of Fail color will remain stable if stored under recommended conditions.

ISO 11140-1:2014, Type 4

Visit www.proppermfg.com/international or call +1 (718) 392-6650 for more information.

More Less

Product category: Chemical indicators for sterilisation

Plasma-Chex VH2O2 Sterilization Indicator Tape

Plasma-Chex VH2O2 Sterilization Indicator Tape
Cat. No.: 26801000 – VH2O2 Indicator Tape – 20 rolls per case

Long Island City, NY – August 22, 2017: New from Propper, Plasma-Chex sterilization indicator tape can be used with packages, pouches and trays as a process indicator for VH2O2 sterilization. It provides immediate identification of sterilized trays and packs with a clear blue/purple to pink color change.

Plasma-Chex Tape is a pressure sensitive tape available in 1" (25 mm) width designed to secure sterilization packages and imprinted with a process indicator – Vaporized Hydrogen Peroxide (VHP) reactive ink. The stripe & dot pattern printed with reactive ink changes color when exposed to VHP (Plasma) sterilization. The tapes are intended to demonstrate exposure to VHP sterilization process and distinguish processed and not processed sterilization packs or items. The color change should not be interpreted as indications of the adequacy of the sterilization cycle. The plastic tape substrate is white in color which does not change during VHP sterilization. 

ISO 11140-1:2014, Type 1

Visit www.proppermfg.com/international or call +1 (718) 392-6650 for more information.

More Less

Product category: Apparatus for cleansing and disinfection

OK-Sonic® Ultrasonic Bath Indicators

OK-Sonic® Ultrasonic Bath Indicators
Cat. No.: 26310200 – 100 indicator strips per pack

Long Island City, NY – August 22, 2017: The Propper Ultrasonic Bath Indicators are designed to provide a challenge to the cleaning efficacy of ultrasonic cleaners helping you safeguard against: Insufficient cavitation, insufficient temperature in short cycles, improper instrument loading/overloading, insufficient detergent presence and water quality issues.

OK-Sonic indicators monitor the strength of cavitation within an ultrasonic cleaner as well as other important parameters such as temperature, detergent presence & concentration, length of cycle using dual soil spots to mimic blood and tissue removal from both surfaces and difficult to clean instrument parts.

The test is easily performed in line with current hospital cleaning procedures as a cycle monitor for your Washer-Disinfector equipment performance and the cycles in use at your facility.

The test features full compliance with ISO 15883, the routine monitoring of washer-disinfectors and can be used in a Cleaning Verification program as per the recommendations of ANSI/AAMI ST-79 and ST-91.

Visit www.proppermfg.com/cleaning-verification or call +1 (718) 392-6650 for more information.

More Less

Product category: Apparatus for cleansing and disinfection

WD-Chex® Washer-Disinfector Indicators

WD-Chex® Washer-Disinfector Indicators
Cat. No.: 26310200 – 250 indicator strips per pack

Long Island City, NY – August 22, 2017: The Propper Washer-Disinfector Indicators are designed to provide a challenge to the cleaning efficacy of washer-disinfectors. The dual indicator imprints mimic the soiling that occurs naturally during use of medical instruments, laboratory glassware and other materials.

WD-Chex indicators monitor the integrated result of the cleaning process parameters, which includes mechanical action of water, efficacy of detergent, cycle time and temperature.

The test is easily performed in line with current hospital cleaning procedures as a cycle monitor for your Washer-Disinfector equipment performance and the cycles in use at your facility. 

The test features full compliance with ISO 15883, the routine monitoring of washer-disinfectors and can be used in a Cleaning Verification program as per the recommendations of ANSI/AAMI ST-79 and ST-91.

Visit www.proppermfg.com/cleaning-verification or call +1 (718) 392-6650 for more information.

More Less

Product category: Apparatus for cleansing and disinfection

Washer-Disinfector Test Soil

Washer-Disinfector Test Soil
Cat. No.: 26100400 – 6 test jars, 6 applicators, 6 stir sticks and 1 dye bottle per box

Long Island City, NY – August 22, 2017: The Propper Washer-Disinfector Test Soil is designed to mimic the soiling that occurs naturally during use of medical instruments, laboratory glassware and other materials. The test is easily performed in line with current hospital cleaning procedures as a validation test for your Washer-Disinfector equipment performance and the cycles in use at your facility. 

The test features full compliance with ISO 15883, the routine monitoring of washer-disinfectors and can be used in a Cleaning Verification program as per the recommendations of ANSI/AAMI ST-79 and ST-91.

Visit www.proppermfg.com/cleaning-verification or call +1 (718) 392-6650 for more information.

More Less

Product category: Apparatus for cleansing and disinfection

ProExposeTM Endo Long Swab Protein Detection Test

ProExposeTM  Endo Long Swab Protein Detection Test
Cat. No.: 26623400 – 4ea Test Vials, 3ea 2.8mm diameter by 2.5m length endoscope swabs, 1ea control swab and 1ea control strip per box

Long Island City, NY – August 22, 2017: The Propper ProExposeTM Endo Long Swab Protein Detection Test provides a way to ensure that channels of rigid and flexible endoscopes, and other potentially contaminated lumens, have been cleaned effectively. It is a simple check designed to detect residual proteins inside the channels of endoscopes by means of a rapid color change observed in the test solution. The test is easily performed in line with current hospital cleaning procedures after cleaning, immediately before high level disinfection or sterilization.

ProExpose Short Swab is sensitive to the wide range of proteins that accumulate as soil/biomaterial on instruments during use. It is semi-quantitative and will detect protein down to a level of ≥ 1μg, with a darker blue color associated with higher quantities of protein.

In addition to yielding fast results with great sensitivity, this protein test is user-friendly. Simply insert the swab into the channel of the endoscope being tested if the channel is recently wet from cleaning, if dry, moisturize the swab with de-ionized water before inserting the swab. Feed the swab through the length of the channel and clip the end of the swab so that can be inserted into the test vial. Swirl the end of the swab in the reagent solution for 5 seconds and observe for any color change. The performance of the test can be verified using the included positive control strips.

The test features full compliance with ISO 15883, the routine monitoring of washer-disinfectors and can be used in a Cleaning Verification program as per the recommendations of ANSI/AAMI ST-79 and ST-91.

Visit www.proppermfg.com/cleaning-verification or call +1 (718) 392-6650 for more information.

More Less

Product category: Apparatus for cleansing and disinfection

ProExposeTM Short Swab Protein Detection Test

ProExposeTM  Short Swab Protein Detection Test
Cat. No.: 26623300 – 30ea Test Vials, 30ea 8cm swabs and 2ea control strips per box

Long Island City, NY – August 22, 2017: The Propper ProExposeTM Short Swab Protein Detection Test provides a way to ensure that an item has been cleaned effectively. It is a simple check designed to detect residual proteins on the surfaces of surgical instruments, rigid and flexible endoscopes, washer-disinfector equipment, ultrasonic cleaners, and other potentially contaminated surfaces by means of a rapid color change observed in the test solution. The test is easily performed in line with current hospital cleaning procedures after cleaning, immediately before high level disinfection or sterilization.

ProExpose Short Swab is sensitive to the wide range of proteins that accumulate as soil/biomaterial on instruments during use. It is semi-quantitative and will detect protein down to a level of ≥ 1μg, with a darker blue color associated with higher quantities of protein.

In addition to yielding fast results with great sensitivity, this protein test is user-friendly. Simply swab the surface being tested if already wet, if dry, moisturize the swab with de-ionized water before swabbing. Swirl the swab in the reagent solution for 5 seconds and observe for any color change. The performance of the test can be verified using the included positive control strips.

The test features full compliance with ISO 15883, the routine monitoring of washer-disinfectors and can be used in a Cleaning Verification program as per the recommendations of ANSI/AAMI ST-79 and ST-91.

Visit www.proppermfg.com/cleaning-verification or call +1 (718) 392-6650 for more information.

More Less

Product category: Chemical indicators for sterilisation

HT Helix Table Top PCD with Onix Strips

HTTM Helix Table Top PCD with Onix Strips
Cat. No.: 26942200 - 1 reusable test device with 250 indicator strips per box

Long Island City, NY – August 22, 2017: Propper is excited to introduce our new HT™ Helix Table Top PCD (Process Challenge Device) test for table top sterilizers.  The HT Helix Table Top PCD monitors the efficacy of the steam sterilization process by presenting an equivalent challenge to a Biological Indicator in the standard AAMI towel pack. The HT Helix Table Top PCD is designed for use as a hollow load release process challenge test for small sterilizers in saturated steam cycles between 126°C to 137°C.

The HT Helix Table Top PCD is sold as 1 reusable test device with 250 OnixTM process challenge indicator strips. The HT Helix Table Top PCD is a re-useable capsule manufactured using a material that heats up and cools down quickly. The device simulates the internal channels of lumen instruments to present an adequate challenge for steam penetration and to ensure that the parameters of the cycle have been achieved for confident load release.

The strips are imprinted with an indicator ink that displays a clear, easy-to-read color change from white to black when all critical parameters for steam sterilization are achieved. This color change is a stable one that will not revert to its original unprocessed color; both pass and fail results are stable for years after processing.  In addition, this new product is an environmentally friendly recyclable strip that is laminate and latex free.

The Helix Table Top PCD offers full compliance with EN 867-5.

Visit www.proppermfg.com/international or call +1 (718) 392-6650 for more information.

More Less