BioMed Jena GmbH Biomedizinische Technik of Jena at MEDICA 2017 in Düsseldorf -- COMPAMED Trade Fair
Manufacturers Service OEM

BioMed Jena GmbH Biomedizinische Technik

Am Egelsee 1, 07743 Jena
Germany

Telephone +49 3641 356900
Fax +49 3641 356909
info@biomed-jena.de

This company is co-exhibitor of
Thüringen c/o medways

Hall map

MEDICA 2017 hall map (Hall 15): stand E21

Fairground map

MEDICA 2017 fairground map: Hall 15

Contact

René Schüler

CEO

Phone
+493641356900

Email
schueler@biomed-jena.de

Tino Gablenz

Head of Development

Phone
+493641356901

Email
gablenz@biomed-jena.de

Our range of products

Product categories

  • 01  Electromedical equipment / Medical Technology
  • 01.01  Diagnostics
  • 01.01.01  General Diagnostics

General Diagnostics

  • 01  Electromedical equipment / Medical Technology
  • 01.01  Diagnostics
  • 01.01.01  General Diagnostics
  • 01.01.01.01  Equipment for audiological diagnostics (audiometer)
  • 01  Electromedical equipment / Medical Technology
  • 01.01  Diagnostics
  • 01.01.01  General Diagnostics
  • 01.01.01.02  Instruments and apparatus for ocular diagnosis

Instruments and apparatus for ocular diagnosis

Our products

Product category: Equipment for audiological diagnostics (audiometer), ENT (ear, nose and throat) diagnostics

eAUDIO USB - modern computer Audiometer

The eAudio USB - is a modern two-channel pure-tone and speech audiometry.
Thanks of using the latest technologies in electronics, it sets new standards in the field of PC audiometry.
The eAudio USB has 3 integrated power amplifier for direct connection of passive speakers. This makes measurement of Intelligibility Level Difference (ILD) and Binaural Intelligibility Level Difference (BILD) possible.

More Less

Product category: Equipment for audiological diagnostics (audiometer), ENT (ear, nose and throat) diagnostics, Neurological diagnosis, appartus and instruments

eABR USB - Auditory evoked potentials

eABR USB - the preamplifier as a complete unit. Integrated into an ergonomic housing, the eABR USB offers the functionality of a large AEP measuring station. Genuine 2-channel technology, battery-powered measurement, state-of-the-art signal processing and easy-to-use software complete the entire package.

More Less

Product category: Equipment for audiological diagnostics (audiometer)

AudioBox

The AudioBox is a modern computer-controlled free-field amplifier for connecting up to 6 passive boxes. The 6 output channels can be assigned 4 input channels. Each input channel can be individually calibrated with up to 50 positions (125 Hz, 250 Hz etc.). Furthermore, the device has, on customer request, 6 output channels with which an event can be displayed.
The AudioBox can be used to extend a conventional audiometer for lateralisation analysis or pediatric audiometry.

More Less

Product category: Equipment for audiological diagnostics (audiometer)

AudioControl

This special keyboard was developed for an ergonomic Audiometry operation. With 2 sliders the volume levels of tone and masking can be controlled. 16 touch buttons enjure absolut silent operation. This keybaord works with eAUDIO USB or with EVIDENT software. For OEM applications the keyboard can easily integrated via a Joystick interface.

More Less

Product category: ENT (ear, nose and throat) diagnostics

eHIT USB - video Head Impuls Test (vHIT)

The beginning of the 20th century clinically introduced by Bárány the bithermal examination has long been the main method of side depended evaluation of the function of the horizontal semicircular canals. In 1988 Halmagyi and Curthoys first time described the so called head impulse test. The development this method to video head impulse test now enables the visualization of vestibuloocular reflex (VOR) and thus an objectification of disorders of all three semicircular canals each side.Now, vHIT become the golden standard for testing the 6 semicircular canals.

More Less

Product category: ENT (ear, nose and throat) diagnostics, Neurological diagnosis, appartus and instruments

eVNG USB - Videonystagmography

The VNG is a diagnostic method that is used by recording eye movements of the differential diagnosis of balance disorders. For an intact sense of balance, the sensorimotor system (sensory perception and movement) is responsible, whose core component is the vestibulookuläre reflex (VOR). By transmitting information from the labyrinth through the vestibular nerve (vestibulocochlear nerve) to core areas in the brain stem and ultimately the eye muscles this reflex enables postural regulation, gaze stabilization and orientation in space. In case of malfunction of the system can cause impairment of balance and dizziness (vertigo). Whit patients ataxia, vegetative symptoms (nausea) or disturbance of gaze stabilization (Nystagmus) can be seen. This Nystagmus is registered using the VNG. Depending on the direction or type of nystagmus is obtained information about the cause and location of the damage to the equilibrium system.

More Less

Product category: ENT (ear, nose and throat) diagnostics, Neurological diagnosis, appartus and instruments

eFRENZEL USB - Video Frenzel System

The eFRENZEL - video frenzel goggles provides ideal conditions for fixation-free observation and recording of eye movements. Furthermore the stimulating maneuvers can also be recorded. At a glance, you can see the movements of the eyes resulting from the maneuver performed. You can create comments and notes for the individual videos.

eFRENZEL USB - available as a software upgrade for eVNG, eHIT,eHIT+ or as stand alone system.

More Less

Product category: ENT (ear, nose and throat) diagnostics, Neurological diagnosis, appartus and instruments

eDVA USB - Dynamic visual acuity during VOR

Dynamic Visual Acuity (DVA) describes visual image stability where the vestibular ocular reflex (VOR) counters head motion by moving the eyes in the opposite direction to maintain a clear view of the world. The eDVAUSB provides static and dynamic visus information in normal subjects such as pilots and athletes and in patients with vestibular or neurological disorders.

Simpler versions of this test involve reading an eye chart while the patient is shaking their head. If the patient must move up two lines on the eye chart to see the characters clearly, then their VOR is considered abnormal. One problem with the simple test is that the character can be read while the patient’s head is stopped. The eDVA USB computerized version will only present the character to the patient when their head is moving at a high velocity where only the VOR is functional and not pursuit. The test is also direction sensitive, so the right and left sides be tested separately. Also vertical directions are possible.

More Less

Product category: ENT (ear, nose and throat) diagnostics, Neurological diagnosis, appartus and instruments

eVEMP USB - Vestibular Evoked Myogenic Potentials (c- and oVEMP)

The cVEMP test measures and analyzes the vestibular evoked myogenic potentials produced by a loud stimulus in the ipsilateral ear. During the derivation, the patient must contribute to the contraction of the sternocleidomastoid, e.g. by pressing the head against the palm. The cVEMP ratio (difference left to right derivative) is calculated automatically. The cVEMP test is a functional test of the otolithic organ and is used for testing the operation of the saccule. It also provides an indication of the function of the nervous equilibrium (N. saccularis).

More Less

Product category: ENT (ear, nose and throat) diagnostics, Neurological diagnosis, appartus and instruments

eSUV USB - subjectiv visual vertikal (SVV) and horizontal

The determination of the subjective visual vertical is a test of the utricle function in the differential diagnosis of the otolithic organ in the balance system. If a healthy person is asked to adjust a light line in the dark so that it is perpendicular to the ground then very reproducible results are obtained that correspond to the actual vertical in the room. The result of this measurement is called "Subjective Visual Vertical" and is made possible by the correctly transmitted information of the otolithic organs (especially the utricle).
Thus the estimation of the SVV provides a useful clinical test of the orticulus function and is a necessary complement to the examination of the saccular function by cVEMP measurements as well as to the examination of the semicircular canals by caloric irrigation and / or the head pulse test. Since the systematic introduction of the SVV in the Clinic, meanwhile different SVV findings could be determined as an indicator of an isolated urticulus deficiency in numerous patients with normal caloric and cVEMP response.

More Less

Product category: ENT (ear, nose and throat) diagnostics, Neurological diagnosis, appartus and instruments

ePOSTURO - mobile system for computer aided Posturography

Posturography is a general term that covers all the techniques used to quantify postural control in upright stance in either static or dynamic conditions. Among them, Computerized dynamic posturography (CDP), also called test of balance (TOB), is a non-invasive specialized clinical assessment technique used to quantify the central nervous system adaptive mechanisms (sensory, motor and central) involved in the control of posture and balance, both in normal (such as in physical education and sports training) and abnormal conditions (particularly in the diagnosis of balance disorders and in physical therapy and postural re-education). Due to the complex interactions among sensory, motor, and central processes involved in posture and balance, CDP requires different protocols in order to differentiate among the many defects and impairments which may affect the patient's posture control system. Thus, CDP challenges it by using several combinations of visual and support surface stimuli and parameters.

The ePOSTURO system allows the static and dynamic posturography (Romberg-quotient, CoG) and an automatic Unterbergs stepping test to be carried out. It can be done with the eVNG/eHIT mask or with a mobile sensor with bluetooth interface.

More Less

Product category: ENT (ear, nose and throat) diagnostics

KALORIstar - Air irrigator with active cooling technology

Bithermal examination in VNG/ENG is still important. The air airrigator KALORIstar gives you an exact tempered air flow. For warm rooms the device has an active cooling installed and can reach 7K below ambient temperature.

More Less

About us

Company data

Export content

max. 50%

Foundation

1997

Area of business

Electromedical equipment / Medical Technology